On the Software Side:
- Create a new instrument configuration in MAGNET Field on the controller
- Choose model: DS-i (Live Video)
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/mf_settings_2_0.jpg?itok=2-558H63)
- Set the TS connection to WiFi
- Choose: Use controller hosted Wi-Fi network.
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/mf_settings_0.jpg?itok=Sbp9XpbT)
- Go to Connect and select the correct instrument profile
- Click Connect
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/connection_0.jpg?itok=izXhjp3V)
- MAGNET Field will ask permission to start the controller hosted network
- Click Yes
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/connection1_0.jpg?itok=8tGmwmcB)
- The network name and password are shown
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/connection2_0.jpg?itok=CN92lq_p)
On the Instrument side:
- Power up the DS-200i
- Click the PRG button
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/external_link.jpg?itok=jnrjqFhT)
- Open External Link
- Click on the button with the bars and the red cross on the right
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/external_link1.jpg?itok=1PrDOefF)
- Select the network called "MAGNET"
- Click Connect. If it is the first time connecting type in the password (123456)
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/external_link2.jpg?itok=ZLfOkq5F)
- The DS-200i should show blue bars on the right side if it's connected
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/external_link3.jpg?itok=v8VPsUjg)
On the Software Side:
- In MAGNET Field select the instrument
- Click Select
![](https://mytopcon.topconpositioning.com/sites/default/files/styles/totalcare_article_side_image/public/totalcare_article/content_images/connection3.jpg?itok=ozADrtfG)